Knowledge · Rules and standards

The rules behind good street lighting

What the standards, EU law and Luxembourg's national guidance say about lighting levels, dimming, energy and light pollution, and what each one means for a commune planning adaptive lighting.

Last reviewed:

lighting classes and energy indicators
EN 13201
lighting classes and energy indicators
yearly energy cut for public bodies (EED)
1.9%
yearly energy cut for public bodies (EED)
colour temperature in the national guide
≤ 3,000 K
colour temperature in the national guide
upward light in the EU procurement criteria
0%
upward light in the EU procurement criteria
At a glance

Seven rules a commune should know

RuleWhat it saysWhat it means for you
EN 13201 (ILNAS-EN 13201)Lighting classes M, C and P with minimum levels; energy indicators PDI and AECI.Design each street to its class. Adaptive lighting moves between classes with traffic, as the standard foresees.
EED (EU) 2023/1791, Art. 5Public bodies cut their combined final energy use by at least 1.9% a year against 2021.In Luxembourg, communes under 50,000 inhabitants count from 2027, under 5,000 from 2030.
EED, Art. 7Contracts above EU thresholds buy high energy efficiency; energy performance contracts are checked.Write metered efficiency and controls into the tender.
Ecodesign 2019/2020 and RoHSEfficiency rules for light sources; mercury exemptions for discharge lamps are running out.Plan the move away from sodium lamps rather than wait for spares to disappear.
Good-lighting guide (2018)3,000 K maximum, amber light in nature reserves, minimal upward light, light on demand.Base the lighting concept on it; the Klimabonus refers to it.
Trame noire study (2024)Dark corridors for wildlife, light on demand, 1,800–1,900 K preferred.Favour adaptive or switch-off solutions along corridors.
Circular 4182 (2022)Recommends switching off between 1:00 and 5:00; each hour off saves about 8%.Where a full switch-off is not acceptable, motion-based lighting is the alternative.
EN 13201

Lighting classes and adaptive lighting

EN 13201 is the European standard for road lighting, applied in Luxembourg as ILNAS-EN 13201. Part 2 sets the performance of each lighting class, part 3 the calculation, part 4 the measurement and part 5 the energy indicators. Part 1, published as a technical report (CEN/TR 13201-1), guides the choice of class from the road's speed, traffic, users and surroundings.

The standard does not oblige anyone to light a road. A 2024 study for the Ministry of the Environment notes that there is no legal obligation to light communal and State roads; where lighting is installed, EN 13201 applies.

EN 13201-1 defines adaptive lighting as controlled changes in luminance or illuminance over time in relation to traffic volume, time, weather or other parameters. When traffic falls, a road can move to a lower class. Motion detection does this street by street, in real time.

Lighting classes

Average levels in EN 13201-2

Maintained average values per class, from the highest to the lowest. Each class also sets uniformity and glare limits not shown here.

ClassesForAverage level
M1 – M6Motorised traffic at medium to high speed2.0 · 1.5 · 1.0 · 0.75 · 0.5 · 0.3 cd/m² (luminance)
C0 – C5Conflict areas such as junctions and roundabouts50 · 30 · 20 · 15 · 10 · 7.5 lx (illuminance)
P1 – P6Pedestrians, cyclists and low-speed traffic15 · 10 · 7.5 · 5 · 3 · 2 lx (illuminance)

Source: EN 13201-2, as reproduced in the JRC technical report on EU green public procurement for road lighting.

EN 13201-5

Measuring energy: PDI and AECI

The power density indicator (PDI, symbol DP) gives the power an installation needs per lux and per square metre lit, in W/(lx·m²), while meeting the lighting class. It compares designs for the same street.

The annual energy consumption indicator (AECI, symbol DE) gives the energy used per square metre per year, in kWh/m², including changes in lighting level through the night and the seasons. This is where dimming and adaptive control show.

Neither indicator compares streets with different geometry or classes. Ask for both, street type by street type, in the tender.

EU energy law

What the Energy Efficiency Directive asks of communes

Article 5 of Directive (EU) 2023/1791 requires the total final energy consumption of all public bodies combined to fall by at least 1.9% a year compared with 2021. Luxembourg applies it from 11 October 2025, as an indicative target until 11 October 2027. Communes under 50,000 inhabitants are excluded until 31 December 2026, communes under 5,000 until 31 December 2029.

The same article asks regional and local authorities to set specific energy-efficiency measures in their long-term plans. Public bodies report their consumption: in 2025 through Klima-Agence, from 2026 on the national Enercoach platform.

Article 7 requires contracting authorities to buy only products, services, buildings and works with high energy efficiency for contracts above the EU procurement thresholds, applying the energy-efficiency-first principle. For service contracts with significant energy use, they must check whether a long-term energy performance contract is feasible.

Lamps and mercury

Ecodesign and the end of discharge lamps

Commission Regulation (EU) 2019/2020 sets ecodesign requirements for light sources and separate control gear and has applied since 1 September 2021. It replaced the earlier regulations under which high-pressure mercury street lamps had already left the market. It also expects luminaires to let light sources and control gear be replaced, unless the manufacturer justifies otherwise.

Mercury in high-pressure sodium lamps is allowed only through exemptions to the RoHS Directive. Delegated Directive (EU) 2022/275 renewed the exemption for standard sodium lamps until 24 February 2027. Renewal requests are under review and the exemption stays valid until the Commission decides, but sodium is a technology on its way out.

Controllers on a Zhaga Book 18 socket follow the same logic as ecodesign: they can be swapped or upgraded without touching the luminaire.

Light pollution and biodiversity

Luxembourg's guidance on good outdoor light

The national guide „Gutes Licht“ im Außenraum (Ministry of Sustainable Development and Infrastructure, 2018) sets a maximum colour temperature of 3,000 K for outdoor lighting, warm white in parks and green zones, and amber light of about 2,200–2,500 K for road-safety lighting in nature reserves and Natura 2000 areas. Technical luminaires should send no more than 0.5% of their light upwards and be mounted horizontally.

The guide allows lighting to follow time or traffic, on the principle of light on demand, as long as EN 13201 is met. The Klimabonus asks that renovated lighting follows the guide.

In 2024 the Ministry of the Environment published a study for a trame noire, a network of dark corridors for nocturnal wildlife. It recommends light-on-demand systems and 1,800–1,900 K where possible, and reports that pilot communes in the Parc Naturel de l'Our cut annual lighting hours from about 4,200 to under 500 with light on demand.

The October 2022 circular on energy saving recommended switching communal street lighting off between 1:00 and 5:00 and estimated that each hour off saves about 8% of the energy. Where a full switch-off is not acceptable, motion-based lighting keeps the street lit for whoever uses it.

Greater Region

Rules across the border

France The arrêté of 27 December 2018 on light nuisance applies to lighting installed since 1 January 2020. It limits the upward light ratio to under 1% and colour temperature to 3,000 K, or 2,700 K in built-up areas and 2,400 K outside them in regional nature parks, and limits flux to 35 lumens per square metre in built-up areas. Luminaires sending more than half their light upwards had to be replaced by 1 January 2025.

Germany Since March 2022, § 41a of the Federal Nature Conservation Act requires new street lighting to avoid harm to insects and other wildlife, with technical details to be set by federal ordinance. New road lighting is generally not allowed in nature reserves outside built-up areas.

Green public procurement

The EU criteria for road lighting

The EU green public procurement criteria for road lighting and traffic signals, published in December 2018 (SWD(2018) 494), are voluntary but widely used in tenders. They ask for at least one pre-set dimming level down to 50% of maximum output or less, dimming or switch-off programmes in parks open at night and other ecologically sensitive areas, and luminaires rated with 0% upward light.

In short

What this means for adaptive lighting

  • Dimming is allowed: the standard foresees lower classes when traffic falls, and the national guide accepts light on demand.
  • The Klimabonus counts dimming or night switch-off only when the light comes back automatically when needed. Motion-based control does exactly that.
  • Each street keeps its designed EN 13201 class whenever someone uses it.
  • Warm colour temperatures, no upward light and fewer hours at full output reduce light pollution.
Next step

Start with one street

Tell us about the street, park or cycle route you have in mind. We survey it, model the savings, help with the Klimabonus application and run the pilot.